Stainless Steel Coil Tube for HVAC Fan Coil Unit Systems

Product Overview

The Stainless Steel Coil Tube (Product No. 1098) manufactured by Wenzhou Jixing Metal Materials Co., Ltd. is a precision-engineered coiled piping solution specifically designed for integration into Fan Coil Unit (FCU) air conditioning systems and related HVAC (Heating, Ventilation, and Air Conditioning) applications. This coil tube product represents a critical heat exchange component that facilitates efficient thermal transfer between circulating refrigerant or hot water media and ambient air within fan coil unit assemblies.

In the context of design-condition verification calculations for fan coil unit air conditioning systems, the coil tube serves as the fundamental heat exchange surface whose geometric parameters, material properties, and thermal characteristics directly determine the system's cooling capacity, heating capacity, and overall energy efficiency. The product is engineered to meet the rigorous demands of variable operating conditions encountered during system commissioning and performance verification.

Material & Properties

Base Material Composition

The coil tube is fabricated from high-grade austenitic stainless steel, predominantly conforming to AISI 304 (UNS S30400) or AISI 316L (UNS S31603) grades, selected for their superior corrosion resistance, thermal conductivity, and mechanical integrity under cyclic thermal loading conditions.

Key Physical and Mechanical Properties

Property AISI 304 AISI 316L Unit
Density (ρ) 7,930 8,000 kg/m³
Thermal Conductivity (λ) at 20°C 16.3 14.6 W/(m·K)
Thermal Conductivity (λ) at 100°C 21.6 19.5 W/(m·K)
Specific Heat Capacity (c) 500 500 J/(kg·K)
Tensile Strength (σb) ≥520 ≥515 MPa
Yield Strength (σs) ≥205 ≥205 MPa
Elongation (A5) ≥40 ≥40 %
Operating Temperature Range -196 to +870 -196 to +870 °C
Corrosion Resistance (ASTM G48) Excellent Superior —

Surface Treatment

Specifications

Parameter Specification Tolerance Standard Reference
Outer Diameter (OD) 6.35 mm / 9.53 mm / 12.7 mm / 15.88 mm (¼" / ⅜" / ½" / ⅝") ±0.10 mm ASTM A213 / EN 10216-5
Wall Thickness 0.50 mm / 0.71 mm / 0.89 mm / 1.00 mm ±0.05 mm ASME B36.19M
Coil Length (per unit) Up to 30 m (continuous) ±0.5 m Manufacturer Specification
Coil Pitch / Row Spacing 12.7 mm – 25.4 mm (adjustable) ±0.3 mm ASHRAE Handbook
Coil Turns per Row 2 – 8 rows (configurable) ±1 turn Project-Specific Design
Fin Type Aluminum L-Channel / V-Crimp / Wavy — ASHRAE Standard 15
Fin Density 10 – 14 fins per inch (FPI) ±1 FPI Industry Standard
Maximum Design Pressure 1.6 MPa (standard) / 2.5 MPa (reinforced) — EN 12163
Hydrostatic Test Pressure 2.4 MPa (standard) / 3.75 MPa (reinforced) — ASME Section VIII
Flow Velocity (Design) 1.0 – 2.5 m/s (water side) — ASHRAE Guideline 34
Heat Transfer Coefficient (U-value) 450 – 650 W/(m²·K) — ASHRAE Fundamentals

Manufacturing Process

Process Flow Overview

  1. Raw Material Inspection: Incoming stainless steel strip or tube undergoes spectroscopic analysis (Optical Emission Spectrometry — OES) to verify chemical composition compliance with ASTM A213/A269 specifications. Mill test certificates (MTC) are cross-referenced with batch traceability records.
  2. Surface Preparation: The base tube material is cleaned, degreased, and passivated using nitric acid or citric acid solutions to remove oxide layers and restore chromium-rich passive film integrity (minimum 20% Cr passive layer coverage verified via ASTM A967).
  3. Precision Coiling: Computer Numerical Control (CNC)-guided coiling machines form the tube into the designated serpentine or helical configuration. The coiling process employs controlled bending radii (minimum 3D bending radius) to prevent ovalization, kinking, or micro-cracking of the tube wall.
  4. Welding and Joining: Inlet and outlet connections are fabricated using TIG (Tungsten Inert Gas) welding with argon shielding. Weld quality is verified through visual inspection (VT) per AWS D10.9 and, where required, dye penetrant testing (PT) per ASTM E707.
  5. Fin Installation: Aluminum fins are mechanically crimped onto the coil tube using high-frequency resistance welding or mechanical expansion methods. Fin-to-tube contact resistance is minimized to ensure optimal thermal coupling.
  6. Pressure Testing: Each coil assembly undergoes hydrostatic pressure testing at 1.5× the maximum design pressure, held for a minimum of 30 minutes to verify leak-tightness and structural integrity.
  7. Performance Verification: Completed coil units are subjected to thermal performance testing in accordance with AHRI (Air-Conditioning, Heating, and Refrigeration Institute) Standard 440/460 to validate heat exchange capacity, pressure drop, and flow distribution characteristics under design conditions.
  8. Final Inspection and Packaging: Dimensional verification, surface quality assessment, and traceability documentation are completed prior to protective packaging and dispatch.

Process Quality Control Points

Stage Inspection Method Acceptance Criteria Standard
Material Verification OES Spectroscopy Composition within ASTM A213 limits ASTM E415
Dimensional Check Laser Micrometer / CMM OD, wall thickness within ±0.10 mm ISO 286
Weld Integrity Dye Penetrant Testing No indications of cracks or porosity ASTM E707
Pressure Test Hydrostatic Gauge Monitoring No pressure drop over 30 min ASME BPV Section VIII
Thermal Performance Calorimetric Test Rig U-value ≥ 450 W/(m²·K) AHRI 440/460

Applications

Primary Application Domain: Fan Coil Unit (FCU) Air Conditioning Systems

The stainless steel coil tube is the core heat exchange element within Fan Coil Unit (FCU) systems. In design-condition verification calculations, the coil tube's performance parameters are critical for determining:

Secondary Applications

Quality Certifications

International Standards Compliance

Product-Specific Certifications

Certification Scope Validity
Mill Test Certificate (MTC) — EN 10204 3.1 Material composition and mechanical property verification per batch Per production lot
Hydrostatic Test Report Pressure integrity verification for each coil assembly Per unit
Non-Destructive Testing (NDT) Report Weld quality and structural integrity documentation Per unit
Third-Party Performance Test Report AHRI/EN-compliant thermal performance validation Per product type
Material Traceability Certificate Full supply chain traceability from raw material to finished product Per production lot

Unique Selling Points

1. Design-Condition Verified Performance: Unlike generic coil tube